10~15mm
Over
50cm
HEAT
RADIATION
FENCE
AWNING
FOAM
COOLED
AIR
70-150cm
Level
1/4
Bubble
Shipping
screws
White
styrofoam
block
Installation
Steps
Hardware
Installation
15
ENGLISH
Select
the
Best
Location
Measure
the
space
for
installation
to
assure
a
good
fit.
The
air
conditioner
must
be
installed
firmly
into
place
to
prevent
vibration
and
noise.
Avoid
exposure
to
direct
sunlight.
Remove
all
obstacles
from
the
rear
of
the
unit.
There
must
be
at
least
50cm
(20in.)
of
cleared
space
around
the
rear
of
the
unit.
Obstacles
restricting
the
airflow
may
reduce
the
cooling
efficiency
of
the
unit.
The
unit
should
be
installed
with
a
slight
tilt
towards
the
outside
(approx.
3°)
to
allow
condensed
water
to
drain.
(About
10~15mm
or
1/4
bubble
with
level)
NOTE:
The
external
grille
must
be
exposed
outside
for
air
discharge.
4
3
2
1
Remove
the
Air
Conditioner
From
the
Case
Remove
2
shipping
screws
from
the
back
of
the
case.
Remove
the
2
screws
on
each
side
of
the
case.
Keep
these
for
later
use.
Slide
out
the
air
conditioner
from
the
case
by
pulling
the
base-pan
handle
while
bracing
the
case.
Remove
the
white
Styrofoam
shipping
block
from
the
compressor.
(Applicable
for
some
models)
4
3
2
1
Attaching
the
Drain
Pan
(Optional)
The
drain
pan
is
used
to
collect
condensed
water.
The
base-pan
may
overflow
due
to
high
humidity.
The
base-pan
may
also
collect
excess
water
when
in
reverse
mode
(in
Reverse
Cycle
models
only).
To
drain
the
excess
water,
remove
the
drain
cap
from
the
back
of
the
unit
and
secure
the
drainpipe
as
follows:
1.
Remove
the
drain
pan
located
in
the
air
discharge
or
on
the
barrier.
2.
Remove
the
rubber
cap
from
the
hole
on
the
base-pan.
(Not
applicable
to
all
models)
3.
Install
the
drain
pan
to
the
left
corner
of
the
cabinet
with
2-4
screws.
4.
Connect
the
drain
hose
to
the
hole
located
on
the
bottom
of
the
drain
pan.
You
can
purchase
the
drain
hose
or
tubing
locally
to
satisfy
your
particular
needs.
(Drain
hose
not
included)