INSTALLATION MANUAL
AIR CONDITIONER
• Please read this installation manual completely before installing the product.
• Installation work must be performed in accordance with the national wiring
standards by authorized personnel only.
• Please retain this installation manual for future reference after reading it
thoroughly.
P/NO : MFL67798112
www.lg.com
TYPE : BUILT - IN DUCT - LOW STATIC
Original instruction
ENGLISH ITALIANO
ESPAÑOL
FRANÇAIS
DEUTSCH
ΕΛΛΗΝΙΚΆ
ČEŠTINA
NEDERLANDS
POLSKI
LIMBA ROMÂNĂ
Przeglądanie stron 0
1 2 3 4 5 6 ... 26 27

Podsumowanie treści

Strona 1 - AIR CONDITIONER

INSTALLATION MANUALAIR CONDITIONER • Please read this installation manual completely before installing the product.• Installation work must be perfor

Strona 2 - TABLE OF CONTENTS

10 Indoor UnitInstallationSuction GrilleSuction GrilleSuction CanvasAir outletAir outletPart name and functionsn B3/B4 Series : Built-in Duct type Con

Strona 3 - Safety Precautions

Installation1. Remove the Air Filter.2. Check the drainage.• Spray one or two glasses of water uponthe evaporator.• Ensure that water flows drain hose

Strona 4

12 Indoor UnitInstallationCAUTIONCeilingDrain Pump useDrainage holeFront of view1. Install declination of the indoor unit is very important for the dr

Strona 5

InstallationHAND OVERTeach the customer the operation and maintenance procedures, using the operation manual. (air filter cleaning, temperature contro

Strona 6

14 Indoor UnitWIERED REMOTE CONTROLLER INSTALLATION• Since the room temperature sensor is in the remote controller, the remote controller box should b

Strona 7 - Installation

22133<Wire guide grooves>InstallationInstallation of Wired Remote Controller1. Please fix tightly using provided screw after placing remote cont

Strona 8 - POSITION OF CONSOLE BOLT

Installation16 Indoor Unit4. Please connect indoor unit and remote controller using connection cable.5. Please use extension cable if the distance bet

Strona 9 - Indoor Unit Installation

Installation14571110982361312Please attach the inform label inside of the door.Please choose proper language depend on your country.1415Name and funct

Strona 10 - Air outlet

Installation18 Indoor UnitDip Switch SettingFor Multi V Models, Dip switch 1, 2, 6, 8 must be set OFF.CAUTIONFunction Description Setting Off Setting

Strona 11 - Checking the Drainage

InstallationGroup Control SettingGNDSignal12 VLGAP Network SystemMaster Slave Slave SlaveDisplay Error MessageOnly connect serial signal and GND lines

Strona 12 - Drainage hole

2 Indoor UnitCeiling Concealed Duct - Low Static Type Indoor Unit Installation ManualTABLE OF CONTENTSo Four type "A" screws o Connecting ca

Strona 13 - HAND OVER

Installation20 Indoor UnitGNDSignal12 VLGAP Network SystemMaster Slave Slave SlaveDisplay Error MessageDonʼt connect serial 12V lineMaster Slave5. In

Strona 14 - (1.5meters)

InstallationGNDSignal12 VLGAP Network SystemMasterSlaveDisplay Error MessageMaster MasterMasterFAUSlaveFAUMasterFAUStandard StandardFAU FAUStandard St

Strona 15 - <Wire guide grooves>

5. Accessories for group control settingIt is possible to set group control by using below accessories.Indoor unit 2 EA +Wired remote controllerIndoor

Strona 16 - Unit side

InstallationENGLISHInstallation Manual 23The A-weighted sound pressure emitted by this product is below 70 dB.** The noise level can vary depending o

Strona 17

24 Indoor UnitHow to Set E.S.P?How to Set E.S.P?If entering into ESP setup mode by using button, it indicates as the picture below.2Select E

Strona 18 - Dip Switch Setting

How to Set E.S.P?Function code, ESP codeESP value Press button to save.7Select ESP fan step again by using button and setup ESP value

Strona 19 - Group Control Setting

26 Indoor UnitHow to Set E.S.P?Note :1. The above table shows the correlation between the air rates and E.S.P.2. E.S.P. is given after subtracting co

Strona 20 - 2. Group Control 2

[Representative] LG Electronics Inc. EU Representative Krijgsman 1, 1186 DM Amstelveen, The Netherlands[Manufacturer] LG Electronics Inc. Changwon 2nd

Strona 21 - 3. Group Control 3

Safety PrecautionsSafety PrecautionsTo prevent injury to the user or other people and property damage, the following instructions must befollowed.n Be

Strona 22 - 4. 2 Remote Control

4 Indoor UnitSafety Precautionsn OperationDo not modify or extend thepower cable.• There is risk of fire or electricshock.Do not let the air condition

Strona 23 - Limiting concentration

Safety PrecautionsAlways check for gas (refrig-erant) leakage after installa-tion or repair of product.• Low refrigerant levels maycause failure of pr

Strona 24 - How to Set E.S.P?

Introduction6 Indoor UnitIntroductionWired Remote ControllerWired Remote ControllerRemote ControllerTEMPRemote ControllerTEMPThis symbol alerts you to

Strona 25 - Installation Manual 25

InstallationInstallationIndoor unitInstall the air conditioner in the location that satis-fies the following conditions.• The place shall easily bear

Strona 26 - (Unit: CMM)

8 Indoor UnitInstallationCeiling dimension and hanging bolt locationInstallation of UnitInstall the unit above the ceiling correctly.• Apply a joint-c

Strona 27

Installation• Select and mark the position for fixing bolts.• Drill the hole for set anchor on the face of ceil-ing.• Insert the set anchor and washer