Przeglądanie stron 5
Type ‘A’ Screw
INSTALLATION PARTS
Installation parts provided with the unit
Type ‘A’ Screw Quantity Shape Others
Type ‘A’ Screw Quantity Shape Others
4
Installation Plate
Type ‘B’ Screw
Holder Remote Control
1
2
1
Paper pattern for
installation.
Owner’s Manual
Installation Manual
Installation parts you must purchase
Paper pattern
for installation.
Owner’s
Manual
Installation
Manual
Sleeve
Bushing Sleave
Putty (Gum type sealer)
Vinyl tape (Wide)
Gas side piping
Liquid side piping
Additional drain pipe
Vinyl tape (Narrow)
Saddle
INSTALLATION PARTS
6
Installation parts you
must purchase
Installation plate
Sleeve
Bushing-Sleeve
Putty(Gum Type Sealer)
Bend the pipe as closely
on the wall as possible,
but be careful that it
doesn't break.
Vinyl tape (Wide)
Apply after carrying out a
drainahe test.
To carry out the drainage
test, remove the air filters
and pour water into the heat
exchanger.
Gas side piping
Liquid side piping
Additional drain pipe
Vinyl tape (Narrow)
Connecting cable: Cooling & Heat pump: 2EA
Cooling only: 1EA
More than 70cm
More than
10cm
More than
60cm
Saddle
More than
10cm
More than
5cm
Air filter
(Left and right
are identical)
More than
20cm
Przeglądanie stron 5