Strona 1 - CONDITIONER

ROOM AIR CONDITIONERFor Split AC Domestic ModelsTYPE : WALL MOUNTEDP/No. MFL39754865_V4MFL39754865Regd. Office: LG Electronics India Pvt. Ltd., A Wing

Strona 2

Electrical Safety• This appliance must be properly grounded. To minimize the risk of electric shock, you must always plug into a grounded outlet.• Do

Strona 3 - Avoid excessive cooling

Using the remote controlYou can operate the air conditioner more conveniently with the remote control. Wireless remote controlUsed to circu-Air Circul

Strona 4 - SAFETY INSTRUCTIONS

12BASIC FUNCTIONSCooling your room(Cooling operation)1 Press to turn on the power.2 Press repeatedly to select the coolingoperation.- is display

Strona 5 - Dos and Don’ts

13Adjusting the air flow direc-tion1 To adjust the direction of the flow verti-cally, press change the air flow direc-tion automatically.- This func

Strona 6

142 Press or to select . 3Press to finish.Turning ON the air conditioner auto-matically at a set time1 Press - The icon below flic

Strona 7

15ADVANCED FUNCTIONSThe air conditioner offers some additional ad-vanced functions.Changing room temperaturequicklyH’COOL(Himalaya)ModeThis mode allow

Strona 8 - Prior to Operation

AIAIAI16ADVANCED FUNCTIONSAuto operation (Optional)(Artificial inelligence)1Press to turn on the power.2Press repeatedly to select auto opera

Strona 9 - Features

17ADVANCED FUNCTIONSOpen the frontpanel upwardON/OFFbutton(Forced Operation)Heat pump Model*Cooling ModelRoom Temp. ³ 24°C 21°C ³ Room Temp. < 24°C

Strona 10 - Using the remote control

consumption.3M filter*MAINTENANCE183 M filter*3M filter.1Use soap solution to clean the heat exchanger coils and the panel vents (consult with technic

Strona 11

MAINTENANCE19Do not press the mesh Caution :Remove the plasma filter after 10 seconds.

Strona 12 - BASIC FUNCTIONS

BEFORE – Prior to operation– Components– Electrical Safety– Using the remote controlInserting BatteriesInstalling the remote control holderWireless Re

Strona 13 - (Air Circulation operation)

MAINTENANCE20Cleaning the 3M Filter(Optional)3M Filter.We suggest changing the 3M Filter every 6 months.- Do not wash the 3M Filter with water beca

Strona 14

TROUBLESHOOTING21call call call call There is a burning smell andan abrupt sound comingfrom the unit.

Strona 15 - ADVANCED FUNCTIONS

TROUBLESHOOTING22Operate the air conditioner on Air circulationmode (Refer to page 13) for 2 to 3 hours.• This will dry out the internal mechanisms.Wh

Strona 16 - * Operation (Optional)

DISCLAIMER23IMPORTANT: Long term effect not tested and mosquitoes may become resistant. Mosquito species used in the test below may differ from the mo

Strona 17 - (Forced Operation)

21INSTALLATION- Do not use sea water for this purpose.windbreak so that outdoor unit

Strona 18 - 3M filter*

TEST RUNNINGBoltTubing connectionCheck that all tubing and wiring have beenproperly connected.Check that the gas and liquid side service valvesare ful

Strona 19 - Do not press

Gas sideLiquid sideCapHexagonal wrench2-way valve(Open)3-way valve(Close)CEvacuationSoap water methodRemove the caps from the 2-way and 3-wayvalves.Re

Strona 20 - Outdoor Unit

Lo HiIndoor unitOutdoor unitManifold valveCharge hoseNitrogen gascylinder(in verticalstanding position)PressuregaugeAir purgingPressure in the system

Strona 21 - TROUBLESHOOTING

Tip of drain hose dipped in waterWaterleakageDitchLess than 50mm gapChecking the drainageDo not make drain piping.Form the pipingDo not raiseWaterleak

Strona 22 - Operation ranges

CONNECTING THE CABLEBETWEEN INDOOR & OUTDOOR UNITConnect the cable to theoutdoor unitARemove the control cover from the unit byloosening the screw

Strona 23 - DISCLAIMER

3reduce the cooling / dehumidication functions. Avoid excessive cooling(Refer page no. 19 and 20 details of owner's manual).

Strona 24 - INSTALLATION

CONNECTING THE CABLEBETWEEN INDOOR & OUTDOOR UNITConnect the cable fromIndoor to outdoor unit.If a power plug is not to be used, provide a circuit

Strona 25 - TEST RUNNING

FLARING WORK AND CONNECTION OF PIPINGBundle the piping and drain hose together bywrapping them with cloth tape over the rangewithin which they fit int

Strona 26 - AIR PURGING

Vinyl tape(narrow)Connecting cablePipeConnectionpipeVinyl tape(wide)Wrap with vinyl tapeIndoor unit pipeVinyl tape(narrow)AdhesiveDrain pipeIndoor uni

Strona 27

Vinyl tape(narrow)Connecting cablePipeConnectionpipeVinyl tape(wide)Wrap with vinyl tapeIndoor unit pipeDrain pipeConnecting cableWrap with vinyl tape

Strona 28 - Downward slope

FLARING WORK AND CONNECTION OF PIPINGConnection of piping-IndoorPreparing the indoor unit's piping and drainhose for installation through the wal

Strona 29 - CONNECTING THE CABLE

Outside diametermmø6.35ø9.52ø12.7ø15.88ø19.05inch1/4"3/8"1/2"5/8"3/4"mm mm1.1~1.3 0.71.5~1.7 0.81.6~1.8 0.81.6~1.81.9~2.1 1.0

Strona 30

Mount the installation plate horizontally byaligning the centerline using a level.AMount the installation plate on the wall withfour type “A” screws.

Strona 31

INSTALLATION OF INDOOR & OUTDOOR UNITRead completely, then follow step by step.Capacity is based on standard length and maximumallowance le

Strona 32

123456789101112Installation ToolsS.No. Required ToolsLevel GaugeScrew DriverElectric DrillHole Core Drill (Dia-70mm)Flaring Tool SetSpecified torque w

Strona 33 - For right rear piping

INSTALLATION PARTSInstallation parts provided with the unitName Shape OthersInstallation parts you must purchaseOwner’sManualInstallationManual••Sleev

Strona 35 - Putting nut on

5SAFETY INSTRUCTIONSAlways check for gas (refrigerant) leakage after installation or repair of product.- Low refrigerant levels may cause failure of p

Strona 36 - Type “A” Screw

4SAFETY INSTRUCTIONSDo not turn ON the MCB/Breaker or power under condition of front panel, cabinet, top cover, control box cover are removed or opene

Strona 37 - Piping length and elevation

3reduce the cooling/ dehumidication functions. Avoid excessive cooling(Refer page no. 19 and 20 details of owner's manual).

Strona 38 - Installation Tools

6 Installation Parts provided with the Unit6 Installation Parts you must purchase7 Installation ToolsINSTALLATION PARTS68-910-14101111121415-161718202

Strona 39 - INSTALLATION PARTS

ROOM AIR CONDITIONERFor Split AC Domestic ModelsTYPE : WALL MOUNTEDP/No. MFL39754865_V4MFL39754865INSTALLATION MANUALRegd. Office: LG Electronics Indi

Strona 40

5Be sure to use only those parts which are listed in the service parts list. Never attempt to modify the equipment. It may result in death, serious in

Strona 41

For inner cleaning, contact an Authorized Service Center or a dealer. Do not use harsh detergent thatcauses corrosion or damage on the unit. Ha

Strona 42

Disposal of your old appliance (as per e-waste Rules)1. When this crossed out wheeled bin symbol is depicted on the product and its operator’s manual

Strona 43 - TIPS FOR SAVING ENERGY

Prior to OperationPreparing for Operation1. Contact an installation specialist for installation.2. Plug in the power plug properly.3. Use a ded

Strona 44

ComponentsSymbols used in this ManualThis symbol alerts you to the risk of electric shock. This symbol alerts you to hazards that may cause harm to th