5.3 Regulation for ULPG
Check that the connection has been made as described in the “Gas
connection” section.
Undo the screw “D” and push the air regulator “C” fully down. Use a
spanner to remove the nozzles “B” and fit those of suitable type
following the instructions given in the tables for ULPG - 2.75 kPa.
The nozzle must not be tightened to a torque of over 3 Nm.
Regulate the air flow by moving the Venturi pipe “C”, until the gap
A” is as shown in the table in point “5.5 Regulation of primary air”
and fix it with the screw “D”. After making the adjustments, restore
the seals with sealing wax or an equivalent material.
ULPG – 2.75 kPa
Nominal gas
Consumption
(MJ/h)
Injector
(mm)
Burner
Auxiliary
Semi-rapid
Rapid
Rapid large
Fish pan
Wok
4.8
5.9
8.6
9.5
9.5
13.2
0.60
0.65
0.77
0.85
0.85
0.98